Fog Machine cord?

Q & A on technical issues concerning music equipment, electronics, sound, recording, computers, gaming, the internet, etc.

Moderators: Ron, Jim Price

Post Reply
User avatar
CMOR
Gold Member
Gold Member
Posts: 367
Joined: Fri Jun 04, 2004 12:52 pm
Location: Right here.
Contact:

Fog Machine cord?

Post by CMOR »

I want to add a fog machine into the lighting setup. My light board has a fog control built in, but I don't have the right cord. Does anyone know where I can get the parts to make one?
If I had pics, I'd post them to see what I have. The ends look like male/female ends of your standard amp or other electronic device cord. My goal is to have the fog machine on or near the stage and obviously the board in the booth with me.
Any help is welcome.

Steve
It's impossible to know the burdens carried by any man or demons that haunt his steps.
User avatar
lonewolf
Diamond Member
Diamond Member
Posts: 6249
Joined: Thu Sep 25, 2003 7:58 pm
Location: Anywhere, Earth
Contact:

Post by lonewolf »

Most of the ones I've seen are 5-pin DIN sockets and are identical to MIDI connectors. With the power off, try plugging a MIDI cable into it and if it fits, that's what you need as far as a connector. I'm not sure of the current requirements of fog machine control, but it should be low enough to use a MIDI cable. If not, you will need to make a signal cable with heavier 5 conductor cable.

I'm also not sure what the pinout is, buy my fog machine only uses 3 conductors. 1 ground, 1 to sense that the machine is ready and one to turn on the fog. Some midi cables only have 3 conductors, so to be on the safe side, make sure that your MIDI cable has 5 conductors, one for each pin.
...Oh, the freedom of the day that yielded to no rule or time...
User avatar
CMOR
Gold Member
Gold Member
Posts: 367
Joined: Fri Jun 04, 2004 12:52 pm
Location: Right here.
Contact:

Post by CMOR »

Thanks Jeff, but it a 3-pin config. If you disconnect the removable power cord from your amp, that's the config. I'm dealing with. I think it's commonly referred to as "3-pin IEC." What I have now just plugs into the back of the fogger to work as a remote switch, just not long enough for the layout.
It's impossible to know the burdens carried by any man or demons that haunt his steps.
User avatar
Ron
Site Admin
Site Admin
Posts: 2034
Joined: Sat Dec 07, 2002 7:03 am
Location: State College, PA

Post by Ron »

Steve,
What kind of connector is the remote out on the light controller?

I've seen fog machines with the 3 pin EIC remote, but I'm not sure what kind of voltage the remote operates on. Since the remote connector is a 3 pin EIC, I would think that it might be operating on 110VAC.

Unless the output on the light controller is a 3 pin EIC, you're probably going to need some type of interface.

You could just extend the EIC cable with something like this http://www.midweststereo.com/ProductDet ... de=ANTEXT2 and use the remote that came with the fogger.
... and then the wheel fell off.
User avatar
lonewolf
Diamond Member
Diamond Member
Posts: 6249
Joined: Thu Sep 25, 2003 7:58 pm
Location: Anywhere, Earth
Contact:

Post by lonewolf »

CMOR wrote:Thanks Jeff, but it a 3-pin config. If you disconnect the removable power cord from your amp, that's the config. I'm dealing with. I think it's commonly referred to as "3-pin IEC." What I have now just plugs into the back of the fogger to work as a remote switch, just not long enough for the layout.
Ahh, gotcha...thats whats on my fog machine. Each blade measures 120V to the ground stud, but I'm not sure of the current.

That connector is called an International Male IEC 320 C14 connector, 3 pin (or 2 pin with ground).

Here, you can import them using Her Majesty's Royal Mail:

http://cgi.ebay.co.uk/Connector-IEC-C14 ... 0181165787

Is that what you need on both ends?

Here is a power extension cable that has one of each ends:

http://www.provantage.com/cables-go-20941~7CBT90J0.htm
...Oh, the freedom of the day that yielded to no rule or time...
User avatar
CMOR
Gold Member
Gold Member
Posts: 367
Joined: Fri Jun 04, 2004 12:52 pm
Location: Right here.
Contact:

Post by CMOR »

That's what I'm looking for. I was just hoping to put one together from Radio Shack or something. I've seen the extensions on Ebay. Guess that's the route I have to go.

Thanks Ron and Jeff
Steve
It's impossible to know the burdens carried by any man or demons that haunt his steps.
User avatar
lonewolf
Diamond Member
Diamond Member
Posts: 6249
Joined: Thu Sep 25, 2003 7:58 pm
Location: Anywhere, Earth
Contact:

Post by lonewolf »

Call Best Buy, Lowe's, Home Despot, Radio Shack or other computer shops 1st. They might have those extensions in stock.
...Oh, the freedom of the day that yielded to no rule or time...
Rich
Gold Member
Gold Member
Posts: 434
Joined: Thu Aug 26, 2004 7:30 pm
Location: Mifflin Co.
Contact:

Fog machine cord...

Post by Rich »

Our light guy just took a 50' heavy duty extension cord, cut the ends and wired it up... Works just fine... Never had a problem with it yet...
Kickin' like a one legged chicken....
Post Reply